NFPA 70E 130.7(C)(10)

What it means on the job

A standard face shield does not provide arc-rated protection for the face and neck. Category 3 requires an arc-rated balaclava worn under an arc-rated face shield and hard hat to protect exposed skin from arc flash burns.

Tested in 1 CraftIQ puzzle

  • whats-wrongUnion Hall Training: Arc Flash PPE Assessment
Practice this code — free

Related NFPA sections

NFPA 652 / NFPA 69 / OSHA 1910.22

Ductwork carrying combustible dust to a collector must have spark detection and/or suppression systems to intercept incendiary sparks before they reach the collector. NFPA 652 (Standard on the Fundamentals of Combustible Dust) and NFPA 69 require spark mitigation for processes that generate sparks, such as grinding, cutting, or welding operations.

NFPA 68 / NFPA 484 / OSHA 1910.94

Aluminum dust is highly combustible and explosive. Dust collectors handling combustible metals must have explosion relief vents sized per NFPA 68 to safely relieve deflagration pressure. Without relief venting, an internal dust explosion can rupture the collector, sending shrapnel and flame into the facility.

NFPA 70E 110.4(B) / 120.1

Damaged test lead insulation can expose the user to electrical shock and can cause phase-to-phase or phase-to-ground short circuits resulting in arc flash. All test equipment must be inspected before each use per NFPA 70E and replaced if damaged.

NFPA 70E 130.7(C)(7) / Table 130.7(C)(7)(a)

When performing energized electrical work such as voltage testing on a 480V MCC, voltage-rated insulating gloves with leather protectors are required. Class 00 or Class 0 gloves are minimum for 480V work, and the shock protection boundaries must be observed.

NFPA 70E Table 130.7(C)(15)(a)

The incident energy analysis on the arc flash label indicates Category 3 hazard. Wearing Category 1 PPE (4 cal/cm²) provides dangerously insufficient protection for a Category 3 exposure (25 cal/cm²). PPE category must meet or exceed the hazard level.

NFPA 72 Section 21.3.5 / IBC 907.3.3

NFPA 72 Section 21.3.5 (Elevator Recall for Fire Fighters' Service) and IBC 907.3.3 (Elevator recall) require smoke detection in elevator machine rooms, machinery spaces, hoistways, and lobbies to initiate elevator recall (Phase I) per NFPA 72 and ASME A17.1. Without a smoke detector, the elevator recall system cannot activate automatically, potentially sending cars to a fire floor and trapping occupants in a smoke-filled hoistway. (Note the code book: elevator recall is IBC 907.3.3 / IFC 606-607, not IBC Chapter 6, which covers Types of Construction.)