OSHA 1910.252 / AWS Z49.1
What it means on the job
Plasma cutting produces intense UV/IR radiation and bright arc flash that causes eye damage (arc eye) and skin burns. A welding screen or curtain must be deployed around the cutting area to protect the operator and nearby workers.
Tested in 1 CraftIQ puzzle
- whats-wrongUnion Hall Safety: Sheet Metal Shop Hazards
Related OTHER sections
OSHA 1910.147(d)(6)
OSHA 1910.147(d)(6) requires the authorized employee to VERIFY that isolation and de-energization have actually been accomplished before starting work — by testing for absence of voltage and attempting a normal start. A handle position is an indication, not a verification. Handles break, contacts weld, and the disconnect you opened is not always the one feeding the equipment.
OSHA 1910.147(e)(3)
OSHA 1910.147 requires each lock to be removed by the employee who applied it. Removal by anyone else is permitted only under a specific documented procedure that includes verifying the employee is not in the facility and informing them before they return to work. A master key kept for convenience defeats the single guarantee the standard provides — that your lock is the only thing that can start that machine while you are inside it.
OSHA 1910.212 / SMACNA Safety Manual
Pittsburgh lock seam machines have pinch points that can amputate fingers. Machine guards are required by OSHA and must never be bypassed or removed. SMACNA apprenticeship training specifically emphasizes: never defeat a machine guard.
OSHA 1910.252(c) / ACGIH TLV Guidelines
OSHA 1910.252(c) requires adequate ventilation for all welding operations. In confined or enclosed spaces, mechanical ventilation must provide a minimum of 2,000 CFM per welder. Welding fumes contain hexavalent chromium, manganese, and other toxic metals that exceed OSHA PELs without proper exhaust ventilation.
OSHA 1926.251 / ASME B30.9 — Slings
Nylon slings in contact with sharp edges must have corner protectors (softeners) to prevent the sling from being cut under load. A sling failure under a 2,000 lb load is a fatal hazard. OSHA and ASME B30.9 require edge protection whenever a sling contacts a sharp radius.
OSHA 1926.753 / ASME B30.5
Suspended loads must have a tag line to allow workers to guide the load without placing hands on it. Without a tag line, workers must physically push/pull the suspended load, putting them in the fall zone — a leading cause of rigging fatalities.