OSHA 1910.119(e)(6)
What it means on the job
This fails OSHA PSM requirements. OSHA 1910.119(e)(6) explicitly requires that the Process Hazard Analysis be updated and revalidated at least every 5 years. The plant's PHA is now 7 years old and 2 years past the mandatory revalidation deadline. The revalidation requirement exists because process conditions, equipment condition, personnel, and industry knowledge of hazards change over time, even without intentional process modifications. Additionally, incident investigations, near-misses, and new regulatory guidance since the original PHA may reveal hazards not previously identified. The 5-year revalidation is mandatory regardless of whether process changes have occurred.
Tested in 1 CraftIQ puzzle
- code-checkOSHA PSM — Process Hazard Analysis Frequency
Related OTHER sections
Manufacturer Installation Guidelines
Thermostat wire connections should use proper terminal blocks or crimp connectors, not wire nuts. Wire nuts on 18 AWG thermostat wire often lose connection over time due to vibration.
NEBB / AABC Procedural Standards
All TAB work must be documented on proper report forms recording design CFM, measured CFM, and final adjusted CFM for every outlet. Without documentation, the work cannot be verified or submitted to the engineer for approval.
NIST SP 800-82 / ASHRAE Guideline 36 — Cybersecurity
BAS controllers must be on a segregated network (VLAN or separate physical network) with firewall protection from general IT traffic. Default passwords must be changed, and access should be restricted to authorized personnel. NIST SP 800-82 provides cybersecurity guidelines for industrial control systems. Unsecured BAS devices have been exploited in real attacks to disrupt building operations and gain access to corporate networks.
OSHA 1910.138 / SMACNA Safety Manual
Raw sheet metal edges are razor-sharp and cause severe lacerations. OSHA and SMACNA safety standards require cut-resistant gloves (ANSI A4 or higher) when handling unfinished sheet metal. This is the #1 injury in sheet metal shops.
OSHA 1910.147 / NFPA 70E 120.5
Removing an MCC bucket while the bus is energized exposes the worker to live 480V bus stabs and creates an arc flash hazard. OSHA 1910.147 and NFPA 70E require the MCC to be de-energized and locked out/tagged out before withdrawing any bucket unless the equipment is specifically designed for hot-swap operation.
OSHA 1910.212 / SMACNA Safety Manual
Pittsburgh lock seam machines have pinch points that can amputate fingers. Machine guards are required by OSHA and must never be bypassed or removed. SMACNA apprenticeship training specifically emphasizes: never defeat a machine guard.