IPC 608.15.4.2

What it means on the job

This is a cross-connection violation. A hose connection that can be submerged below the flood-level rim creates a backflow hazard. The dirty mop water in the sink could be siphoned back into the potable water supply during a back-siphonage event. A listed atmospheric vacuum breaker (ASSE 1001) or hose connection vacuum breaker (ASSE 1011) must be installed on the hose bibb.

Tested in 2 CraftIQ puzzles

  • whats-wrongResidential Water Supply Piping
  • code-checkCross-Connection at Utility Sink
Practice this code — free

Related IPC sections

CraftIQ explanations are original educational commentary written in trade language and verified against the cited standards. Always confirm requirements against the code edition adopted by your jurisdiction — this is training material, not a substitute for the code book or your AHJ.